Library
| Title | Categories | Model | Description | Quantity | Status |
|---|---|---|---|---|---|
| CEM Sound Level Meter | Sound Reading |
Model:
DT-8852 |
Description:
Instrument for noise monitoring. Plugs into computer via USB. This meter conforms to the IEC61672-1 Class 2 and ANSI S1.4 Type 2 standards. | 2 | AVAILABLE |
| Circuit Breaker Finder | Electricity |
Model:
61-534 | 1 | AVAILABLE | |
| CO2 Monitor | Air Quality | Ventilation |
Model:
Telaire 7001 |
Description:
Identify areas with low or substandard ventilation. Identify hidden energy savings in over-ventilated spaces. Determine if ventilation is a factor in air quality complaints. Locate the presence of combustion fumes from vehicles and appliances. Use as a reference to calibrate wall mounted CO2 sensors. Telaire 7001 with Onset cable to hook to hobo and 120 V. adaptor 6V, 500mA output | 1 | AVAILABLE |
| Continental Control Systems, LLC ACT Split-Core CT | Current Transformer |
Model:
ACT-0750-020 |
Description:
Current Transformers (CTs) measure the amount of electricity flowing in a circuit. CTs are used with a WattNode meter, which also measures voltage. | 6 | AVAILABLE |
| Continental Control Systems, LLC ACT Split-Core CT | Current Transformer |
Model:
ACT-0750-005 |
Description:
Current Transformers (CTs) measure the amount of electricity flowing in a circuit. CTs are used with a WattNode meter, which also measures voltage. | 6 | AVAILABLE |
| Dent CONTACTlogger | Energy | Power | 55 | AVAILABLE | ||
| Dent ElitePro Energy Logger, High Memory, Line power | Electrical | 17 | AVAILABLE | ||
| Dent Flexible Unterminated CT | Current |
Model:
CT-FLN, 3000A | 12 | AVAILABLE | |
| Dent MAGlogger | Energy | Power | 6 | AVAILABLE | ||
| Dent RoCoil mV | Current Transformer |
Model:
CT-RMV-16-1000 RoCoil mV.5" window, 20-5kA |
Description:
Like its name implies, the RoCoil mV produces a millivolt output for use with DENT’s ELITEpro and DATApro Series dataloggers. Available in standard lengths up to 72” and current ranges up to 6000A. The RoCoil mV requires 5-24V dc, which can be supplied from the Line-Powered ELITEpro or optional external power supply. | 23 | AVAILABLE |
| Dwyer Magnehelic | Air Pressure | 3 | AVAILABLE | ||
| Dwyer Portable Analog Signal Generator | Electrical |
Model:
ASG |
Description:
The Model ASG is a handheld analog signal generator. It generates a 0-10 VDC signal in increments of 1V or a 0-20 mA signal in increments of 2 mA. The LED bar graph visually indicates analog signal level. It can also continuously ramp to user-defined minimum or maximum values with user-defined ramp-time settings. | 1 | AVAILABLE |
| EME Systems Amp | Light Reading |
Model:
UTA/BNC/hobo-200 |
Description:
Convert Li-Cor micro Amp out put into a voltage to supply a signal to a HOBO data logger. Output max voltage can be user seleced on the amp. The Amp should be reconfigured for use | 2 | AVAILABLE |
| EME Systems Amp | Light Reading |
Model:
UTA/BNC/hobo-210 |
Description:
Convert Li-Cor micro Amp out put into a voltage to supply a signal to a HOBO data logger. Output max voltage can be user seleced on the amp. The Amp should be reconfigured for use under indoor vs. outdoor environment. The max light level encountered needs to be considered with selecting max voltage out. | 7 | AVAILABLE |
| Extech Light Meter | Light Reading |
Model:
EA33 |
Description:
The EA33 takes high intensity light measurements. Using the EA33's 50-reading memory, this light meter can store up to 50 measurements with either a relative or a real time clock stamp. | 2 | AVAILABLE |
| Extech Thermo-Anemometer | Temperature |
Model:
CFM-CMM, HD300 |
Description:
Measures remote surface temperatures to 932°F (500°C) with 30:1 distance to spot ratio and Laser pointer; Simultaneous display of Air Flow in CFM/CMM or Air Velocity plus Ambient Temperature | 2 | AVAILABLE |
| FLIR E50bx | Infrared Camera |
Model:
E50bx |
Description:
The FLIR E50 is a compact easy to use thermal imaging camera designed for electrical and mechanical inspectors. | 1 | AVAILABLE |
| Fluke AC/DC Current Clamp | Current |
Description:
Fluke I410 AC/DC current clamp measures from .5A to 400 amps. Hall effect, battery powered, output 1mV per 1 amp AC or DC | 2 | AVAILABLE | |
| Fluke Infered Thermometers | Spot Readings | Temperature |
Model:
62 Mini IR Thermometer |
Description:
Non contact infered therometer to measure surface temperatures in deg. C or F. Will not work well on very shinny surfaces (high emissivity). Temp range 0-525 F. | 3 | AVAILABLE |
| Fluke RMS Multimeter | HVAC |
Model:
116 |
Description:
The Fluke 116 was specifically designed for the HVAC professional. It has every-thing needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors. | 2 | AVAILABLE |
| HOBO Current Transformer 100 Amp | Current Transformer |
Model:
CTV-C, 0-100Amp | 8 | AVAILABLE | |
| HOBO Current Transformer 20 Amp | Current Transformer |
Model:
CTV-A, 0-20Amp | 61 | AVAILABLE | |
| HOBO Current Transformer 200 Amp | Current Transformer |
Model:
CTV-D, 0-200Amp | 5 | AVAILABLE | |
| HOBO Current Transformer 50 Amp | Current Transformer |
Model:
CTV-B, 0-50Amp | 10 | AVAILABLE | |
| HOBO Energy Logger Pro | Data Logger | 6 | AVAILABLE | ||
| HOBO FlexSmart TRMS Module | Data Logging |
Model:
S-FS-TRMSA |
Description:
The Logger is a modular, reconfigurable data logging system used in energy and idustrial monitoring applications. The 15-channel sustem enables the user to quickly and easily perform a broad range of monitoring applications. You can use the HOBO FlexSmart Logger with a number of Smart Sensors. It can also be sued with FlexSmart signal conditioning modules to covert signals from many types of Onset and third party sensors. HOBOware software communicates with the logger, allowing you to customize the configuration settings, download data from the Logger, and plot the data for analysis. | 29 | AVAILABLE |
| HOBO Temperature Sensor | Data Logging |
Model:
TMC6-HD |
Description:
A temperature sensor for use with HOBO U-Series external-channel data loggers, this model measures temperature in air, water, or soil. Accuracy and resolution vary according with attached logger model. Measurement range is -40° to 50°C (-40° to 122°F) in water or soil, -40° to 100°C (-40° to 212°F) in air; response time is minutes typical to 90% in air moving 1 m/sec (2.2 mph); response time in stirred water is 1 minute typical to 90%. | 14 | AVAILABLE |
| HOBO U12-006 Data Logger | Data Logging |
Model:
U12-006 |
Description:
Four channel indoor logger. | 19 | AVAILABLE |
| HOBO U12-008 Data Logger | Data Logging |
Model:
U12-008 | 3 | AVAILABLE | |
| HOBO U12-012 Data Logger | Data Logging |
Model:
U12-012 |
Description:
The HOBO U12 Logger can record Temperature, Relative Humidity, and Light with 12-bit resolution and can record up to 43,000 measurements or events. The external channel accepts a variety of sensors, including temperature, and split-core AC current sensors as well as 4-20 mA | 57 | AVAILABLE |
| HOBO U12-013 Data Logger | Data Logging |
Model:
U12-013 | 14 | AVAILABLE | |
| HOBO U8 Data Logger | Data Logging |
Model:
U8 | 8 | AVAILABLE | |
| HOBO Voltage Input Leadset | Data Logging |
Model:
WNB-Leadset | 1 | AVAILABLE | |
| Konica Minolta Illuminance Meter | Light |
Model:
T-10 Main Body | 1 | AVAILABLE | |
| Konica Minolta Luminance Meter | Light Reading |
Model:
LS-110 | 1 | AVAILABLE | |
| LI-COR Photometric | Light Reading |
Model:
LI-210SA |
Description:
The LI-210 Photometric Sensor utilizes a filtered silicon photodiode to provide a spectral response that matches the CIE curve within ± 5% with most light sources. Some of the applications for the LI-210 Photometric Sensor include interior and industrial lighting, outdoor illuminance, passive solar energy, architecture and lighting models, illumination engineering, and biological sciences that require illuminance measurements. The LI-210 is a research grade photometric sensor that is very reasonably priced. | 15 | AVAILABLE |
| LI-COR Pyranometer | Light Reading |
Model:
LI-200SA |
Description:
The LI-200 Pyranometer measures solar radiation received from a whole hemisphere – suitable for measuring global sun plus sky radiation. | 4 | AVAILABLE |
| Magnelab AC Current Transformer (CT) Connection | Current Transformer |
Model:
SCT-0750-050 50 Amp Current Transformer |
Description:
Current transformers, often used with the HOBO flexsmart logger. Use correnct transformer size for voltage being measured. Small then rated voltage can be measured by passing the wire throught the C/T several times. See insturction guide for details. http://www.magnelab.com/ | 9 | AVAILABLE |
| Monarch RHTemp Track-It Logger | Temperature |
Model:
5396-0201 | 40 | AVAILABLE | |
| Nikon D70s | Camera |
Model:
D70s |
Description:
Digital SLR camera can be used to create High Dynamic Range (HDR) images with illuminance data or for site photos. | 2 | AVAILABLE |
| Pulse Input Adapters | Data Logging |
Model:
S-UCA/B-M006 |
Description:
The Pulse Input Adapters are used to log the number of switch closures per interval and are designed to work with the HOBO Weather Station and Micro Station data loggers. The adapter has a plug-in modular connectore that allows it to be added easily to the Weather Station or Micro Station. Two versions are available for easy interfacing with either mechanical contact closures or solid-state electronic switches. The contact closure version is ideal for connecting to tipping bucket rain gauges. | 2 | AVAILABLE |
| Smoke Pen | Air Flow | 1 | AVAILABLE | ||
| Split-core CT, 200 Amp | Current |
Model:
CT-SCT, 200A | 6 | AVAILABLE | |
| Split-Core Mini CT, 20 Amp | Current | 151 | AVAILABLE | ||
| Split-Core Mini CT, 50 Amp | Current Transformer |
Description:
"Split-Core" Current Transformer (SCT) provides linear output voltage that is directly proportional to the input current. This current transformer is easily and safely installed over existing electrical power lines without disconnecting the lines or interrupting service. They are used for a variety of applications including building automation, performance verification, energy management and new technology assessment.Brands, Magnalab, Dent Instruments, Onset Computer Corp. | 66 | AVAILABLE | |
| Veris Industries Hawkeye Current Switch | Data Logging |
Model:
H600 |
Description:
The H600 is a current-sensitive switching device which monitors current (amperage) in the conductor passing through it. A change in amperage in the monitored conductor which crosses the switch threshold will cause the resistance of the status output to change state, similar to the action of a mechanical switch. In this model, the threshold is fixed at 150mA AC max (200mA AC for 50Hz operation). The status output is suitable for connection to building controllers, or other appropriate data acquisition equipment operating at up to 30 volts. The H600 requires no external power supply to generate its output. | 6 | AVAILABLE |
| WattNode Pulse Output kWh Transducer_WNA-3Y-208-P | Electricity |
Model:
0A09P5 |
Description:
The WattNode offers precision energy and power measurements. The WattNode enables you to make precise power and energy measurements from within existing electric service panels. The WattNode is designed for use in demand side management (DSM), sub-metering, and energy monitoring applications. The WattNode outputs a stream of pulses whose frequency is proportional to the instantaneous power and whose count is proportional to total watt-hours. | 4 | AVAILABLE |
| WattNode Pulse Output kWh Transducer_WNB-3D-480-P | Electricity |
Description:
The WattNode offers precision energy and power measurements. The WattNode enables you to make precise power and energy measurements from within existing electric service panels. The WattNode is designed for use in demand side management (DSM), sub-metering, and energy monitoring applications. The WattNode outputs a stream of pulses whose frequency is proportional to the instantaneous power and whose count is proportional to total watt-hours. | 2 | AVAILABLE | |
| Watts up Pro ES Meter | Electricity Meter |
Description:
Plug into any 120 VAC appliance and will display the wattage being used, as well as the cost in dollars and cents | 10 | AVAILABLE |
