Library

TitleCategoriesModelDescriptionQuantityStatus
CEM Sound Level MeterSound Reading
Model: 
DT-8852
Description: 

Instrument for noise monitoring. Plugs into computer via USB. This meter conforms to the IEC61672-1 Class 2 and ANSI S1.4 Type 2 standards.

2AVAILABLE
Circuit Breaker FinderElectricity
Model: 
61-534
1AVAILABLE
CO2 MonitorAir Quality | Ventilation
Model: 
Telaire 7001
Description: 

Identify areas with low or substandard ventilation. Identify hidden energy savings in over-ventilated spaces. Determine if ventilation is a factor in air quality complaints. Locate the presence of combustion fumes from vehicles and appliances. Use as a reference to calibrate wall mounted CO2 sensors. Telaire 7001 with Onset cable to hook to hobo and 120 V. adaptor 6V, 500mA output

1AVAILABLE
Continental Control Systems, LLC ACT Split-Core CT Current Transformer
Model: 
ACT-0750-020
Description: 

Current Transformers (CTs) measure the amount of electricity flowing in a circuit. CTs are used with a WattNode meter, which also measures voltage.
The current and voltage measurements are used by the meter to to calculate power and energy (kW and kWh).
Standard Accuracy
Accuracy: ±0.75% from 1% to 120% of rated primary current
Phase angle: ±0.50 degrees (30 minutes) from 1% to 120% of rated current
IEEE C57.13 accuracy: class 1.2 from 1% to 120% of rated current
IEC 60044-1 accuracy: class 1.0 from 1% to 120% of rated current
Note: The ACT-0750-250 specifications apply at 120% of rated current only at temperatures of 40°C and below.

6AVAILABLE
Continental Control Systems, LLC ACT Split-Core CTCurrent Transformer
Model: 
ACT-0750-005
Description: 

Current Transformers (CTs) measure the amount of electricity flowing in a circuit. CTs are used with a WattNode meter, which also measures voltage.
The current and voltage measurements are used by the meter to to calculate power and energy (kW and kWh).
Standard Accuracy
Accuracy: ±0.75% from 1% to 120% of rated primary current
Phase angle: ±0.50 degrees (30 minutes) from 1% to 120% of rated current
IEEE C57.13 accuracy: class 1.2 from 1% to 120% of rated current
IEC 60044-1 accuracy: class 1.0 from 1% to 120% of rated current
Note: The ACT-0750-005 specifications apply at 120% of rated current only at temperatures of 40°C and below.

6AVAILABLE
Dent CONTACTloggerEnergy | Power55AVAILABLE
Dent ElitePro Energy Logger, High Memory, Line powerElectrical17AVAILABLE
Dent Flexible Unterminated CTCurrent
Model: 
CT-FLN, 3000A
12AVAILABLE
Dent MAGloggerEnergy | Power6AVAILABLE
Dent RoCoil mVCurrent Transformer
Model: 
CT-RMV-16-1000 RoCoil mV.5" window, 20-5kA
Description: 

Like its name implies, the RoCoil mV produces a millivolt output for use with DENT’s ELITEpro and DATApro Series dataloggers. Available in standard lengths up to 72” and current ranges up to 6000A. The RoCoil mV requires 5-24V dc, which can be supplied from the Line-Powered ELITEpro or optional external power supply.

23AVAILABLE
Dwyer MagnehelicAir Pressure3AVAILABLE
Dwyer Portable Analog Signal GeneratorElectrical
Model: 
ASG
Description: 

The Model ASG is a handheld analog signal generator. It generates a 0-10 VDC signal in increments of 1V or a 0-20 mA signal in increments of 2 mA. The LED bar graph visually indicates analog signal level. It can also continuously ramp to user-defined minimum or maximum values with user-defined ramp-time settings.

1AVAILABLE
EME Systems AmpLight Reading
Model: 
UTA/BNC/hobo-200
Description: 

Convert Li-Cor micro Amp out put into a voltage to supply a signal to a HOBO data logger. Output max voltage can be user seleced on the amp. The Amp should be reconfigured for use

2AVAILABLE
EME Systems AmpLight Reading
Model: 
UTA/BNC/hobo-210
Description: 

Convert Li-Cor micro Amp out put into a voltage to supply a signal to a HOBO data logger. Output max voltage can be user seleced on the amp. The Amp should be reconfigured for use under indoor vs. outdoor environment. The max light level encountered needs to be considered with selecting max voltage out.

7AVAILABLE
Extech Light MeterLight Reading
Model: 
EA33
Description: 

The EA33 takes high intensity light measurements. Using the EA33's 50-reading memory, this light meter can store up to 50 measurements with either a relative or a real time clock stamp.

2AVAILABLE
Extech Thermo-AnemometerTemperature
Model: 
CFM-CMM, HD300
Description: 

Measures remote surface temperatures to 932°F (500°C) with 30:1 distance to spot ratio and Laser pointer; Simultaneous display of Air Flow in CFM/CMM or Air Velocity plus Ambient Temperature

2AVAILABLE
FLIR E50bxInfrared Camera
Model: 
E50bx
Description: 

The FLIR E50 is a compact easy to use thermal imaging camera designed for electrical and mechanical inspectors.

1AVAILABLE
Fluke AC/DC Current ClampCurrent
Description: 

Fluke I410 AC/DC current clamp measures from .5A to 400 amps. Hall effect, battery powered, output 1mV per 1 amp AC or DC

2AVAILABLE
Fluke Infered ThermometersSpot Readings | Temperature
Model: 
62 Mini IR Thermometer
Description: 

Non contact infered therometer to measure surface temperatures in deg. C or F. Will not work well on very shinny surfaces (high emissivity). Temp range 0-525 F.

3AVAILABLE
Fluke RMS MultimeterHVAC
Model: 
116
Description: 

The Fluke 116 was specifically designed for the HVAC professional. It has every-thing needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors.

2AVAILABLE
HOBO Current Transformer 100 AmpCurrent Transformer
Model: 
CTV-C, 0-100Amp
8AVAILABLE
HOBO Current Transformer 20 AmpCurrent Transformer
Model: 
CTV-A, 0-20Amp
61AVAILABLE
HOBO Current Transformer 200 AmpCurrent Transformer
Model: 
CTV-D, 0-200Amp
5AVAILABLE
HOBO Current Transformer 50 AmpCurrent Transformer
Model: 
CTV-B, 0-50Amp
10AVAILABLE
HOBO Energy Logger ProData Logger6AVAILABLE
HOBO FlexSmart TRMS ModuleData Logging
Model: 
S-FS-TRMSA
Description: 

The Logger is a modular, reconfigurable data logging system used in energy and idustrial monitoring applications. The 15-channel sustem enables the user to quickly and easily perform a broad range of monitoring applications. You can use the HOBO FlexSmart Logger with a number of Smart Sensors. It can also be sued with FlexSmart signal conditioning modules to covert signals from many types of Onset and third party sensors. HOBOware software communicates with the logger, allowing you to customize the configuration settings, download data from the Logger, and plot the data for analysis.

29AVAILABLE
HOBO Temperature SensorData Logging
Model: 
TMC6-HD
Description: 

A temperature sensor for use with HOBO U-Series external-channel data loggers, this model measures temperature in air, water, or soil. Accuracy and resolution vary according with attached logger model. Measurement range is -40° to 50°C (-40° to 122°F) in water or soil, -40° to 100°C (-40° to 212°F) in air; response time is minutes typical to 90% in air moving 1 m/sec (2.2 mph); response time in stirred water is 1 minute typical to 90%.

14AVAILABLE
HOBO U12-006 Data LoggerData Logging
Model: 
U12-006
Description: 

Four channel indoor logger.

19AVAILABLE
HOBO U12-008 Data LoggerData Logging
Model: 
U12-008
3AVAILABLE
HOBO U12-012 Data LoggerData Logging
Model: 
U12-012
Description: 

The HOBO U12 Logger can record Temperature, Relative Humidity, and Light with 12-bit resolution and can record up to 43,000 measurements or events. The external channel accepts a variety of sensors, including temperature, and split-core AC current sensors as well as 4-20 mA

57AVAILABLE
HOBO U12-013 Data LoggerData Logging
Model: 
U12-013
14AVAILABLE
HOBO U8 Data LoggerData Logging
Model: 
U8
8AVAILABLE
HOBO Voltage Input LeadsetData Logging
Model: 
WNB-Leadset
1AVAILABLE
Konica Minolta Illuminance MeterLight
Model: 
T-10 Main Body
1AVAILABLE
Konica Minolta Luminance MeterLight Reading
Model: 
LS-110
1AVAILABLE
LI-COR PhotometricLight Reading
Model: 
LI-210SA
Description: 

The LI-210 Photometric Sensor utilizes a filtered silicon photodiode to provide a spectral response that matches the CIE curve within ± 5% with most light sources. Some of the applications for the LI-210 Photometric Sensor include interior and industrial lighting, outdoor illuminance, passive solar energy, architecture and lighting models, illumination engineering, and biological sciences that require illuminance measurements. The LI-210 is a research grade photometric sensor that is very reasonably priced.

15AVAILABLE
LI-COR PyranometerLight Reading
Model: 
LI-200SA
Description: 

The LI-200 Pyranometer measures solar radiation received from a whole hemisphere – suitable for measuring global sun plus sky radiation.

4AVAILABLE
Magnelab AC Current Transformer (CT) ConnectionCurrent Transformer
Model: 
SCT-0750-050 50 Amp Current Transformer
Description: 

Current transformers, often used with the HOBO flexsmart logger. Use correnct transformer size for voltage being measured. Small then rated voltage can be measured by passing the wire throught the C/T several times. See insturction guide for details. http://www.magnelab.com/

9AVAILABLE
Monarch RHTemp Track-It LoggerTemperature
Model: 
5396-0201
40AVAILABLE
Nikon D70sCamera
Model: 
D70s
Description: 

Digital SLR camera can be used to create High Dynamic Range (HDR) images with illuminance data or for site photos.

2AVAILABLE
Pulse Input AdaptersData Logging
Model: 
S-UCA/B-M006
Description: 

The Pulse Input Adapters are used to log the number of switch closures per interval and are designed to work with the HOBO Weather Station and Micro Station data loggers. The adapter has a plug-in modular connectore that allows it to be added easily to the Weather Station or Micro Station. Two versions are available for easy interfacing with either mechanical contact closures or solid-state electronic switches. The contact closure version is ideal for connecting to tipping bucket rain gauges.

2AVAILABLE
Smoke PenAir Flow1AVAILABLE
Split-core CT, 200 AmpCurrent
Model: 
CT-SCT, 200A
6AVAILABLE
Split-Core Mini CT, 20 AmpCurrent151AVAILABLE
Split-Core Mini CT, 50 AmpCurrent Transformer
Description: 

"Split-Core" Current Transformer (SCT) provides linear output voltage that is directly proportional to the input current. This current transformer is easily and safely installed over existing electrical power lines without disconnecting the lines or interrupting service. They are used for a variety of applications including building automation, performance verification, energy management and new technology assessment.Brands, Magnalab, Dent Instruments, Onset Computer Corp.

66AVAILABLE
Veris Industries Hawkeye Current SwitchData Logging
Model: 
H600
Description: 

The H600 is a current-sensitive switching device which monitors current (amperage) in the conductor passing through it. A change in amperage in the monitored conductor which crosses the switch threshold will cause the resistance of the status output to change state, similar to the action of a mechanical switch. In this model, the threshold is fixed at 150mA AC max (200mA AC for 50Hz operation). The status output is suitable for connection to building controllers, or other appropriate data acquisition equipment operating at up to 30 volts. The H600 requires no external power supply to generate its output.
Go/No switch used with state logger-dent

6AVAILABLE
WattNode Pulse Output kWh Transducer_WNA-3Y-208-PElectricity
Model: 
0A09P5
Description: 

The WattNode offers precision energy and power measurements. The WattNode enables you to make precise power and energy measurements from within existing electric service panels. The WattNode is designed for use in demand side management (DSM), sub-metering, and energy monitoring applications. The WattNode outputs a stream of pulses whose frequency is proportional to the instantaneous power and whose count is proportional to total watt-hours.

4AVAILABLE
WattNode Pulse Output kWh Transducer_WNB-3D-480-PElectricity
Description: 

The WattNode offers precision energy and power measurements. The WattNode enables you to make precise power and energy measurements from within existing electric service panels. The WattNode is designed for use in demand side management (DSM), sub-metering, and energy monitoring applications. The WattNode outputs a stream of pulses whose frequency is proportional to the instantaneous power and whose count is proportional to total watt-hours.

2AVAILABLE
Watts up Pro ES MeterElectricity Meter
Description: 

Plug into any 120 VAC appliance and will display the wattage being used, as well as the cost in dollars and cents

10AVAILABLE

2012 Fall Lecture Series
This season's series has concluded and will be available for viewing in our video archives soon!

IdahoPower commented on Congratulations Idaho Power!, Apr 15, 2013 - [View comment]